HIPOTS (High Voltage Testers)

HIPOTS (High Voltage Testers) / DC High Voltage Testers - Series DPC

  • » Compact, rugged and portable BDV testers for DC dielectric withstand / breakdown testing of electrical equipments.
  • » Panel mounted controls & indicators with easy legend.
  • » Solid state latest SMPS technology
  • » Digital readout in kV and leakage in mA. Extra digital leakage meter for HV side
  • » Set over voltage limit
  • » Ripple factor: < 3%.
  • » Stability of output: < 1.5%.
  • » Accuracy of measurement: 3% 2 digits
  • » Zero start up.
  • » Visual indication of status of test
  • » Light Weight
  • Model Range Weight
    DPC-60-5 60kV/5mA DC 10 kg
    DPC-80-5 80kV/5mA DC 16 kg
    DPC-120-5 120kV/5mA DC 21 kg



HIPOTS (High Voltage Testers) / AC Hipots : 5 kV Analog

  • » Variable from 0-5 kV.
  • » Multi-range kV & mA meters.
  • » Zero start interlock protection.
  • » Selectable trip current.
  • » Visual indication of status of test.
  • Model Range
    HJ-5-50 5kV / 50 mA AC
    HPD-5-50 5kV / 50 mA DC
    (Models with customized ranges also available)



HIPOTS (High Voltage Testers) / AC Hipots : 5 kV Digital

  • » Panel mounted controls & indicators.
  • » Variable from zero to 5 kV.
  • » Digital kV and leakage mA meter.
  • » Zero start interlock protection.
  • » Selectable trip current.
  • » Visual indication of status of test.
Model Range
HJD-5-50 5kV / 50 mA AC
HPDD-5-50 5kV / 50 mA DC



HIPOTS (High Voltage Testers) / AC, AC & DC Hipots : uP Operated

  • » Compact, rugged and portable BDV testers for AC or AC/ DC dielectric withstand / breakdown testing of electrical equipments.
  • » Voltage ramp up and down function.
  • » Upper and lower preset function for leakage current.
  • » Over voltage and over current protection.
  • » Large VFD display with key parameters display in large font size.
  • » Rise-time control function
  • » Alarm, simple and convenient testing.
  • » Ergonomic design, completely user friendly-just 10 kg.
Model Range
HTU-5 0.2 - 5kV AC, 100mA, 10V per step
HTU-AD 0.1 - 5kV AC, 100mA, 10V per step
0.1 - 6kV DC, 10mA, 10V per step


 

HIPOTS (High Voltage Testers) / AC Hand Gloove and Boot Safety Tester

  • » Compact and rugged BDV testers for AC dielectric withstand / breakdown testing of Safety glooves and boots.
  • » Panel mounted controls and indicators with easy to follow legend.
  • » Continuously variable test voltage from zero to 30, 50 kV.
  • » 500-1000-2000 V / secrate of rise of test voltage.
  • » Multi-range kV and leakage mA meters.
  • » Zero start interlock.
  • » Selectable trip current.
  • » Timer of 1-3-5 minutes.
  • » Audio + Visual alarms.
  • » Safety fixture to hold 2 numbers of item under test.
  • » Test jigs and chambers.



HIPOTS (High Voltage Testers) / AC Hipots: HT Series

  • » Compact and rugged BDV testers for AC dielectric withstand / breakdown testing of electrical equipments.
  • » Panel mounted controls & indicators with easy legend.
  • » Motorized control for continuously variable output voltage.
  • » Multi-range analogue kV & leakage mA meter.
  • » Zero start interlock.
  • » Selectable trip current.
  • » Timer of 1-3-5 minutes.
  • » Audio + Visual indication of status of test.



HIPOTS (High Voltage Testers) / DC Hipots: HPD Series

  • » Compact and rugged BDV testers for DC dielectric withstand / breakdown testing of electrical equipments.
  • » Panel mounted controls & indicators with easy legend.
  • » Continuously variable output voltage.
  • » Output Polarity can be reversed.
  • » Double range analogue kV & leakage mA meter.
  • » Zero start interlock.
  • » Audio + Visual alarm at trip.
  • » Visual indication of status of test.
  • » Timer of 1-3-5 minutes.
  • Model Range
    HPD-20-20 20kV / 20mA AC
    HPD-30-20 30kV / 20mA DC
    HPD-40-20 40kV / 15mA DC
    HPD-50-15 50kV / 15mA DC
    HPD-75-10 75kV / 10mA DC
    (Models with customized ranges also available)



HIPOTS (High Voltage Testers) / AC & DC Hipots: HPACD Series

  • » Compact, rugged and portable BDV testers for AC+DC dielectric withstand / breakdown testing of electrical equipments.
  • » Panel mounted controls and indicators with easy legend.
  • » Continuously variable output voltage AC or DC.
  • » Polarity in DC can be reversed.
  • » Multi-range kV and leakage mA meters.
  • » Zero start interlock.
  • » Audio + Visual indication of status of test.
  • Model Range
    HPACD-10 10kV/10mA DC+ 10kV/10mA AC
    HPACD-20 20kV/10mA DC + 15kV/10mA AC
    HPACD-30 30kV/10mA DC + 20kV/10mA AC
    HPACD-40 40kV/10mA DC + 30kV/10mA AC
    HPACD-50 50kV/6mA DC + 35kV/10mA AC
    HPACD-75 75kV/5mA DC + 50kV/10mA AC
    (Models with customized ranges also available)



HIPOTS (High Voltage Testers) / AC & DC Hipots: HYD Series

  • » Compact and rugged BDV testers for AC+ DC dielectric withstand / breakdown testing of electrical equipments.
  • » Panel mounted controls and indicators with easy to follow legend.
  • » Motorized control for continuously variable output voltage.
  • » Positive DC output at earth potential.
  • » Double range analogue kV and leakage mA meters.
  • » Zero start interlock.
  • » Timer of 1-3-5 minutes.
  • » Audio + Visual alarms at trip.
  • Model Range
    HYD-70 70kV / 100mA AC , 90kV / 50mA DC
    HYD-100 100kV / 100mA AC , 140kV / 50mA DC
    (Models with customized ranges also available)



HIPOTS (High Voltage Testers) / DC High Voltage Testers - Series DPW

  • » Compact, rugged and portable BDV testers for DC dielectric withstand / breakdown testing of electrical equipments.
  • » Panel mounted controls & indicators with easy legend.
  • » Switch mode technology utilizing pulse width modulation
  • control.
  • » Digital readout in kV and leakage in µA / mA.
  • » Ripple factor: ? 0.1%.
  • » Stability of output: ? 0.5%.
  • » Accuracy of measurement: +1.5% + 2 digits
  • » Zero start up.
  • » Audio + Visual indication of status of test
  • » LIGHT WEIGHT; Single unit construction.
  • Model
    Range
    Weight
    DPW-30-5
    30kV/5mA DC
    9.5 kg
    DPW-40-5
    40kV/5mA DC
    10 kg
    DPW-60-5
    60kV/5mA DC
    14.5 kg



HIPOTS (High Voltage Testers) / DC High Voltage Testers - Series GEZ

  • » Compact, rugged and portable BDV testers for DC dielectric withstand / breakdown testing of electrical equipments
  • » Panel mounted controls & indicators with easy legend.
  • » Switch mode technology utilizing pulse width modulation control.
  • » Digital readout in kV and leakage.
  • » Ripple factor: 0.35%.
  • » Stability of output: 0.5%.
  • » Accuracy of measurement: +1.5% + 2 digits.
  • » Zero start up.
  • » Audio + Visual indication of status of test
  • » LIGHT WEIGHT; Two unit construction.
  • Model
    Range
    Weight
    GEZ-80-5
    80kV/5mA DC
    7+17 kg
    GEZ-120-5
    120kV/5mA DC
    7+20 kg
    GEZ-160-2
    160kV/2mA DC
    7+20 kg
    GEZ-200-5
    200kV/5mA DC
    16+23 kg
    GEZ-250-5
    250kV/5mA DC
    16+25 kg